High Permeability Permalloy 1J79 Strip For Precision Magnetic Shielding Applications
Ultra-Low Coercivity Permalloy 80 Foil & Strip with High Initial Permeability for Maximum Low-Frequency EMI Attenuation and Sensitive Current Transformer Cores
- Overview
- Features
- Specifications
- Applications
- Guide
- About DLX
- FAQ
- Recommended Products
Product Overview
Permalloy 80 (1J79) soft magnetic strip is a high-permeability nickel-iron flat alloy for transformer cores, magnetic shields and sensitive devices. As a premium Permalloy grade, this 1J79 strip delivers low coercivity and excellent magnetic uniformity. DLX Alloy provides Permalloy 80 strip in thin gauges with consistent, high permeability.
Whether utilized as flexible magnetic shielding tape, fabricated shielding cans for aerospace avionics, or precision toroidal cores for sensitive instrumentation, DLX Permalloy 80 (1J79) strip guarantees reliable electromagnetic interference (EMI) attenuation and high saturation induction efficiency across demanding industrial environments.

Key Characteristics
-
Ultra-High Magnetic Permeability at Low Fields: Delivers industry-leading initial () and maximum () permeability, providing instantaneous magnetic response and superior low-frequency EMI attenuation.
-
Extremely Low Coercive Force & Hysteresis Loss: Coercivity as low as after optimal final hydrogen heat treatment, drastically reducing operational core losses.
-
Ultra-Precision Dimensional Tolerances: Tight cold-rolling thickness tolerances within with clean slit burr-free edges, ideal for automated high-speed stamping and lamination stacking.
-
Superior Formability & Deep-Drawability: Excellent cold working plasticity in the unannealed/semi-hard state allows intricate bending, stamping, and deep drawing before magnetic annealing.
-
Stable High-Purity Metallurgy: Manufactured via ultra-clean Vacuum Induction Melting (VIM) and Electroslag Remelting (ESR) with tightly controlled impurity thresholds (Carbon , Sulfur).

Technical Specifications
Chemical Composition (Nominal Weight %)
| Element | Nickel (Ni) | Molybdenum (Mo) | Manganese (Mn) | Silicon (Si) | Carbon (C) | Phosphorus (P) | Sulfur (S) | Iron (Fe) |
|---|---|---|---|---|---|---|---|---|
| Standard Range (%) | 78.5 – 80.0 | 3.80 – 4.20 | 0.60 – 1.10 | 0.30 – 0.50 | Balance |
Typical Magnetic & Physical Properties (Post-Hydrogen Annealed State)
| Property Parameter | Value (Metric Units) | Technical Reference / Condition |
|---|---|---|
| Initial Permeability () | () | Weak magnetic field excitation |
| Maximum Permeability () | ( | Peak flux density response |
| Saturation Magnetic Flux Density () | () | |
| Coercive Force () | () | Measured post dry hydrogen anneal |
| Curie Temperature () | Ferromagnetic transition point | |
| Electrical Resistivity () | () | , aids Eddy current reduction |
| Density | Ambient temperature | |
| Annealed Hardness | Soft annealed state |
Available Supply Dimensions & Delivery Conditions
| Form | Thickness (mm) | Width (mm) | Delivery Tempers | Surface Finish |
|---|---|---|---|---|
| Precision Strip & Ribbon | Cold Rolled (Hard / Semi-Hard / Soft Annealed) | Bright Rolled / Pickled / Degreased | ||
| Ultra-Thin Foil / Tape | Light Cold Worked / As-Rolled | Mirror Bright / Ultra-Smooth |
Industrial Applications
1J79 permalloy strip is the premier engineering material for applications requiring superior magnetic field isolation and low-loss inductive performance:
-
Precision Electromagnetic Shielding Enclosures: Custom stamped magnetic shielding cans, cylindrical covers, and multi-layer flexible shielding wraps for photomultiplier tubes (PMT), oscilloscope displays, audio transformers, and medical MRI sensor components.
-
Instrument Transformers & Current Sensors: Ultra-sensitive toroidal wound cores, Zero-Sequence Current Transformer (ZSCT) laminations, and fluxgate magnetometer cores requiring minimal phase shift.
-
Relay & Actuator Components: Magnetic pole pieces, sensitive relays, and magnetic modulator cores in telecommunication switching systems.
-
Aerospace & Defense Electronics: High-reliability navigation shielding enclosures, gyroscope magnetic screens, and compact avionic sensors operating under strict magnetic interference limits.

Processing & Heat Treatment Guide
Important Note for Mechanical Fabrication & Tooling:Permalloy 80 (1J79) achieves its peak magnetic permeability only after final high-temperature magnetic annealing. Mechanical machining, deep drawing, stamping, or bending introduces lattice distortion and internal stress that significantly degrades magnetic properties.
- Pre-Treatment Cleaning: Completely degrease and remove all lubricants, cutting oils, and carbon residues from the stamped parts prior to entering the furnace.
- Furnace Atmosphere: Perform heat treatment strictly in a pure dry hydrogen atmosphere (Dew Point ) or high vacuum () to prevent oxidation and decarburization.
- Heating Cycle: Heat to and hold for to achieve grain boundary optimization and residual stress relief.
- Critical Cooling Rate: Cool slowly at down to , then apply controlled cooling between and o fine-tune the nickel-iron atomic ordering structure for maximum initial permeability.

Why Choose Us
-
Direct Manufacturer & Advanced Metallurgical Control: Established integrated production line encompassing vacuum induction melting (VIM), precision electroslag refining, hot forging, continuous cold strip rolling, and slitting facilities.
-
High-Capacity Scalability: Monthly production capacity reaching 1,200 metric tons, ensuring stable batch-to-batch chemical homogeneity, dependable lead times, and global volume supply security.
-
Comprehensive Quality Verification: 100% material inspection with full traceable mill test reports, including optical emission spectroscopy (OES), raw strip dimensional profile testing, and post-annealing DC/AC magnetic performance validation.
-
Custom Slitting & Protective B2B Packaging: Slit to exact customer width specifications with deburred edges. Packed in anti-rust VCI film, desiccated vacuum wrapping, and reinforced seaworthy wooden crates for safe international container transit.


Frequently Asked Questions
Q1: What is the primary difference between Permalloy 80 (1J79) and 1J50 (50Ni-Fe) soft magnetic alloys?
A1: 1J79 contains approximately 79-80% nickel with molybdenum additions, providing much higher initial () and maximum () magnetic permeability in weak magnetic fields, making it the ideal choice for sensitive magnetic shielding and low-amplitude sensor cores. In contrast, 1J50 offers higher saturation flux density () and is preferred when operating at higher magnetic field strengths where higher saturation resistance is critical.
Q2: Should Permalloy 80 (1J79) strip be stamped in the soft annealed or cold-rolled hard state?
A2: We recommend stamping and punching intricate shapes in the cold-rolled (hard or semi-hard) state to achieve clean cut edges, minimal burrs, and high dimensional accuracy. After all forming, stamping, or welding processes are completed, the finished components must undergo high-temperature hydrogen annealing to restore and maximize the alloy's peak magnetic performance.
Q3: Can DLX Alloy supply custom narrow widths and ultra-thin foil thicknesses?
A3: Yes. Our high-precision slitting lines accommodate ribbon widths down to and ultra-thin foil gauges starting from (), backed by customized coil inner diameters and spool winding options.
Q4: How does mechanical stress impact Permalloy 80 (1J79) magnetic shielding parts after heat treatment?
A4: Permalloy 80 is extremely sensitive to physical shock, dropping, heavy clamping, and elastic deformation after final magnetic annealing. Any mechanical stress disrupts magnetic domain orientation and causes an immediate drop in permeability. Annealed shielding parts must be handled with care and mounted without excessive mechanical clamping pressure.